7 EICR Rules Every UK Landlord Must Know
Last Updated: November 5, 2026
Quick Summary
Yes. EICR landlords in England must arrange an Electrical Installation Condition Report every five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, and must act on any C1 or C2 fault within 28 days.
The five-year clock runs from the inspection date on the report, not the date you received it.
A report is satisfactory only if it contains no C1 or C2 codes.
Give existing tenants a copy within 28 days and new tenants a copy before they move in.
Supply the local authority with a copy within seven days of a written request.
An unsatisfactory report does not reset when a new tenancy starts, as the duty follows the property.
Table of Contents
Is an EICR Mandatory for Landlords? The Short Answer
Yes. If you let property in England, you must arrange an EICR every five years. The rules come from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, and they apply to most private tenancies.
An EICR, or Electrical Installation Condition Report, is a formal inspection and testing document that records the condition of the fixed wiring, sockets, consumer unit and earthing in a property. It tells you whether the installation is safe to use. It also flags anything that needs fixing.
Here is the part most guides get wrong: the report itself is not the goal. The goal is a satisfactory result, backed by any repair work the inspector calls for. A landlord with a valid report but ignored faults is not compliant.
Below, we break down the seven rules every landlord should know, from inspection intervals to what happens when a report comes back unsatisfactory.
How Often Is an EICR Required for Landlords?
Every five years, at minimum. A qualified person must inspect and test the electrical installation at least once every five years, and you must get a new report each time.
There are two exceptions:
A new report is needed sooner if the previous report set a shorter interval.
A new report is needed sooner if the local authority asks for one in writing.
The five-year clock runs from the inspection date on the report, not the date you received it. Keep that date visible. Missing it is one of the most common compliance failures we see.
For a practical look at how long the visit itself takes, our guide on how long an EICR takes walks through timescales for different property sizes.
Which Properties and Tenancies the Rules Cover
The rules cover most private rented homes in England. That includes flats, houses, bedsits and properties let on assured shorthold tenancies.
Leon Rygol
The dividing line is simple. Private rented sector landlords carry the duty. Social rented sector landlords follow their own regulator's standards, which also require periodic inspection but under a different framework.
EICR Rules by Nation: England, Wales, Scotland and Northern Ireland
The four nations do not share one rulebook, and the differences are not cosmetic. They sit in different legislation, use different enforcement mechanisms and, in some cases, cover different tenancy types. If you own property in more than one nation, treat each property as a separate compliance file.
Nation | Governing rules | Scope | Inspection interval | Sharing duties |
England | Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 | Most private tenancies, including ASTs, flats, houses and bedsits | At least every 5 years, or sooner if the report specifies | Tenant within 28 days of inspection; new tenant before occupation; local authority within 7 days of a written request |
Wales | Renting Homes (Wales) Act 2016 and the associated electrical safety duties | Most occupation contracts in the private rented sector | At least every 5 years, or sooner if the report specifies | Contract-holder and local authority, following the Welsh notice and supply rules |
Scotland | Private Rented Housing (Scotland) Act 2011 and the Repairing Standard | Private rented houses and flats covered by the Repairing Standard | At least every 5 years, with the report forming part of the Repairing Standard evidence | Tenant and local authority, in line with Repairing Standard duties |
Northern Ireland | Private Tenancies Act (Northern Ireland) 2022 and the associated electrical safety duties | Most private tenancies in the private rented sector | At least every 5 years, or sooner if the report specifies | Tenant and district council, following the Northern Ireland supply rules |
The core duty for EICR landlords is similar everywhere: inspect, test, act on any C1 or C2 finding, and share the report. The detail is where landlords come unstuck.
England. The 2020 Regulations are the most prescriptive of the four. They impose a hard 28-day deadline for giving the report to existing tenants, a before-occupation deadline for new tenants, and a seven-day deadline for supplying a copy to the local authority on written request.
Wales. The Renting Homes (Wales) Act 2016 replaced the old tenancy framework with occupation contracts, and the electrical safety duties sit alongside the fitness-for-human-habitation requirements.
Scotland. The Repairing Standard is the anchor. An EICR is one of the pieces of evidence a landlord needs to show the standard is met, and the five-year cycle is the accepted interval.
Northern Ireland. The Private Tenancies Act (Northern Ireland) 2022 introduced electrical safety duties for private landlords, with district councils as the enforcement body. The five-year interval applies, and the supply duties run to the tenant and, on request, to the council.
Watch out: a report that is valid in England is not automatically valid in Scotland or Northern Ireland. The inspection itself is broadly similar, but the surrounding duties, notice periods, who receives the report, and which body enforces, are not interchangeable.
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 Renting Homes (Wales) Act 2016 Repairing Standard guidance for private landlords Private Tenancies Act (Northern Ireland) 2022
EICR Report Codes C1 C2 and C3 Explained
Every fault in a report gets a condition code. The code tells you how urgent the problem is, and it decides whether the report passes.
C1: Danger present. Someone could be injured right now. The inspector should isolate the fault or make it safe before leaving.
C2: Potentially dangerous. A real risk exists and needs urgent remedial work.
C3: Improvement recommended. Not unsafe today, but worth fixing.
FI: Further investigation. The inspector needs to dig deeper before grading the fault.
A report is satisfactory only if it contains no C1 or C2 codes. One C1 or C2 makes the whole report unsatisfactory, even if everything else is fine.

C3 codes do not fail a report. They are a to-do list, not an emergency. Clearing them before the next inspection is sensible, because small issues can become C2s.
The EICR Remedial Work Deadline and What Happens Next
You have 28 days from the inspection date to complete remedial work for any C1 or C2 fault, or the shorter period the report specifies if the inspector has set one. That deadline is fixed, and it applies whether or not a tenant is in place. The clock runs from the inspection date on the report, not the date you received it.
The deadline is only half the job. The other half is proving what you did, because landlords who cannot show when a fault was fixed or by whom are more exposed to a compliance notice.
A practical response plan, code by code:
Read the report against the schedule of inspections. Every observation is numbered and carries a code. List every C1 and C2 separately from the C3s and FIs. Do not rely on the summary page alone; the detail is in the schedule.
Treat C1 as an emergency. A C1 means danger is present. The inspector should have isolated or made safe before leaving, but you still need a qualified electrician to carry out the permanent repair. Do not wait for the 28-day window if the circuit is still live.
Book C2 remedial work immediately. A C2 is potentially dangerous and makes the whole report unsatisfactory. Book a qualified electrician, get a written quotation that references the observation numbers, and keep the quotation with the report.
Decide on C3s and FIs deliberately. A C3 is improvement recommended and does not fail the report, but leaving a cluster of C3s to roll into the next cycle is how small issues become C2s. An FI means the inspector could not reach a conclusion and needs to investigate further, treat it as unresolved until the investigation is done and the observation is re-coded.
Get a retest or a remedial certificate. For C1 and C2 work, ask the electrician for a minor electrical installation works certificate or a new EICR covering the remediated circuits, whichever is appropriate.
Write to the tenant and the local authority. Confirm in writing which observations were remediated, on what date, and by whom. Keep the sent item.
File everything together. Original report, quotation, invoice, certificate, tenant letter and local authority correspondence should sit in one file per property, retained for at least the period covered by the report.
Watch out: an unsatisfactory report does not reset when a new tenancy starts. The duty follows the property, not the tenancy, so a change of tenant is not a reason to delay remedial work. Local authorities can serve a compliance notice requiring the work to be done within a specified period, and failure to comply can lead to a financial penalty. Check the enforcement policy for the area where the property sits.
A practical point on evidence: photographs of the remediated consumer unit, dated and referenced to the observation numbers, can be useful if a dispute arises later.
Sharing the EICR: Copy for Tenants and the Local Authority
You must give a copy of the report to each existing tenant within 28 days of the inspection. New tenants must get a copy before they move in, or at the start of the tenancy at the latest.
You must also supply a copy to the local authority within seven days if they ask for it in writing. Keep a record of when you sent it and to whom.
Sending it by email, keeping the sent item, and storing a PDF alongside your tenancy file gives you a clear paper trail if a dispute arises.
Book Your EICR with a Part P Registered Team
Compliance comes down to one thing: using a competent person and acting on what they find. Bright Sparx Electrical is Part P Registered, 18th edition compliant, and fully certified and insured. Our in-house team carries out the work, so you do not need a second contractor to fix what was flagged.
We provide a free full inspection, and fair and transparent pricing is part of how we work. For current prices or a quote, visit our website. If you are unsure how to vet an electrician before booking, read our guide on finding reliable electrical contractors. Then get in touch with Bright Sparx Electrical to arrange your EICR.
Frequently Asked Questions
Is an EICR legally required for landlords?
Yes, for private landlords in England. Landlords in England must arrange an EICR every five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Check the official guidance for the nation where the property sits. The duty applies to the fixed electrical installation, not to appliances.
How often is an EICR required for landlords?
The standard interval is every five years, or sooner if the report specifies a shorter retest date. Keep the certificate on file and diarise the next due date.
What happens if a landlord does not have an EICR?
The local authority can serve a compliance notice, and failure to comply can lead to enforcement action. The simplest protection is to book the inspection before the current report expires and keep proof of every test and repair.
Do landlords have to give tenants a copy of the EICR?
Yes. In England, existing tenants must receive a copy of the report, and the same report must go to the local authority on request. Keep a dated record of how and when you supplied the report, as proof matters if a dispute arises over compliance.